WPI/用于微型传感器/普通/氧气-微型AOT的光纤氧气计

价格
¥210360.00
货号:OXY-MINI-AOT
浏览量:127
品牌:wpiinc
服务
全国联保
正品保证
正规发票
签订合同
商品描述
Overview

A generation of sensors based on luminescence lifetime

  • Oxygen is not consumed during the experiment
  • Immune to electrical and magnetic interference
  • Excellent long-term stability
  • No lengthy polarization necessary (like Clark-type O2 electrodes)
  • Fast response time < 0.5 s for MicroTip sensors
  • Probe size of MicroTip sensors as small as 50 µm
  • Measurement is feasible in dry gas
  • Optical isolation of sensor tip available for fluorescent or photosynthetically active samples
Details

Click here to view the current Data Sheet.

Benefits

  • Unaffected by light source stability and intensity fluctuations, because it is based on luminescence lifetime detections.
  • Compact, portable meters may be used inside or outside

Applications

  • Process control like bottling plant in breweries and quality control of packages (OxyMini)
  • Biotechnology like control of cell culture media and non-invasive control of bioreactors (OxyMini)
  • Implantation of oxygen sensors into soil and trees (OxyMini)
  • Oxygen profiles of marine sediment, soils, or tissue (OxyMicro)
  • Implantation in living tissue like heart or muscle tissue (OxyMicro)
  • Control of cell culture media in Biotechnology (OxyMicro)

The measurement principle of the sensor system is based on the detection of oxygen concentration as a function of luminescence lifetime, either in dissolved or gaseous phase environments.

Unaffected by light source stability/intensity

Conventional fiberoptic oxygen sensor systems based on intensity measurements are limited in their accuracy by light source stability and ambient light fluctuations. Using a luminescence lifetime detection, measurements are not affected by light source stability, intensity fluctuations caused by fiber bending or changes of the optical properties of the sample (turbidity, refractive index, coloration, etc.).

Calibration: The sensors can be calibrated by a simple two point calibration, 100% air-saturation and 0% air saturation.

Compact, portable meters, inside and outside

The OxiMini and OxyMicro fiber optic oxygen meters are compact, easy to transport. Designed for in/outdoor use, they can be connected to a PC via a RS232 interface. Data can be visualized, analyzed and stored with supplied software. A full range of sensors are available.

OxyMini systems

The OxyMini is a one channel fiber optic O2 meter for fiber optic O2 minisensors. These sensors are based on 2 mm polymer optical fibers and have a length of 2.5 m.

MiniTip – This dipping probe (501641) has a tip diameter of 4mm and consists of a polymer optical fiber with an O2 sensitive coating. Its range is 0–100%. It has a response time (t90) of ~ 40 s.

MiniFlow – The MiniFlow probe (501642) is a miniaturized fiber optic chemical sensor integrated in a standard T-shape flow through cell which can be easily connected via Luer-Lock adapters to external tubings. Liquids can be pumped through the cell. It has a response time (t90) of approximately 40 s and an excellent long-term stability.

MiniFoil – Sensor material on a 1cm2 support disk made of polyester can be glued inside glass vials. Measure oxygen concentration non-invasively, non-destructively from outside through the wall of the vial. Illuminate the sensor foil with a plastic fiber optic cable (501644, 01645). The wall of the flask must be transparent/non-fluorescent. (Response time (t90) of ~50s.) The material can be implanted into animal tissues or custom-made housings.

The OxyMini system is optimized for process control and biotechnology applications. The measurement principle of the sensor system is based on the detection of oxygen concentration as a function of luminescence lifetime either in dissolved or gaseous phase environments. The fiber optic oxygen meter is compact and easy to transport. It was designed for in/outdoor use and can be connected to a PC via a RS232 interface. Data can be visualized, analyzed and stored with the supplied software. A full range of sensors covering most biomedical applications are available.

Measurement Principle

Conventional fiber-optic oxygen sensor systems based on intensity measurements are limited in their accuracy by light source stability and ambient light fluctuations. Using a luminescence lifetime detection, measurements are not affected by light source stability, intensity fluctuations caused by fiber bending or changes of the optical properties of the sample (turbidity, refractive index, coloration, etc.). These advantages make WPI"s OxyMini and OxyMicro the most advanced and reliable fiber-optic oxygen system available.

Calibration

The sensors can be calibrated by a simple two point calibration, 100% air-saturation and 0% air saturation.

Resources

OxyMini Instruction Manual

Specifications
MiniTipMiniFlowMiniSpotMicroTipMicroFlowMicroImplant
MEASURE RANGEDISSOLVED/GASEOUS0-45 ppm, 0-100%0-760 mmHg0-45 ppm, 0-100%0-760 mmHg0-45 ppm, 0-100%0-760 mmHg0-45 ppm, 0-100%0-760 mmHg0-45 ppm, 0-100%0-760 mmHg0-45 ppm, 0-100%0-760 mmHg
RESPONSE TIME [T₉₀]DISSOLVED/GASEOUS40 s10 s40 s10 s40 s10 s< 2 s< 0.5 s< 2 s< 0.5 s< 2 s< 0.5 s
STERILIZATIONETOH, H₂O₂AUTOCLAVABLE*YNYYYYYNYYYY
DRIFT**< 0.1%< 0.1%< 0.1%< 0.3%< 0.3%< 0.3%
ACCURACY***0.2%
RESOLUTION***2.75 ±0.01 ppm, 9.00 ±0.05 ppm, 220 ±0.15 ppm, 45.0 ±0.25 mmHg,150 ±0.75 mmHg, 375 ±2.6 mmHg
TEMP RANGE-10°C to 50°C
PROBE ASSY LENGTH2.5 m
*130°C, 1.5 atm **100,000 data points, 20°C ***20°C
Reviews
光谱学 光学测量所需的一切 WPI现在提供全套组件和解决方案,从专有的合格光纤,光学组件到完全集成的光谱测量系统。WPI知道进行科学测量的重要性,因为我们拥有全系列的反射和透射浸入式探头,光纤O2和pH探头以及长光程流通池,所有这些都消除了将样品带到仪器的需求。我们位于德国弗里德贝格的光子学卓越中心也使我们能够快速构建成熟的定制配置。这是用于探头,光学组件还是定制测量系统的新光学设计。