ZYMO RESEARCH/DNA清洁浓缩器-100/50 Preps/D430

价格
¥3420.00
货号:D4030
浏览量:127
品牌:ZYMO RESEARCH
服务
全国联保
正品保证
正规发票
签订合同
商品描述
Clean-up PCR and other enzymatic reactions in as little as 2 minutes
Highlights

  • Simple, rapid recovery of ultra-pure DNA from PCR, endonuclease digestions, and cell-free DNA preps, etc.
  • Unique column construction allows sample loading and washing to be performed using a centrifuge, microcentrifuge, or vacuum source.
  • Eluted DNA is well suited for use in PCR, DNA sequencing, DNA ligation, endonuclease digestion, RNA transcription, radiolabeling, arrays, etc.
Description

The DNA Clean & Concentrator-100 (DCC-100) is a PCR purification kit designed for the rapid desalting and purification of up to 100 µg of high quality DNA from PCR, large format restriction endonuclease digestions, or cell-free lysates. Eluted DNA is suitable for nucleotide sequencing, array analysis, PCR, nucleotide blotting, restriction endonuclease digestion procedures, as well as many other downstream applications requiring high quality DNA. The entire DNA purification/concentration procedure typically takes less than 20 minutes and can be performed using a syringe, centrifuge or vacuum source together with a microcentrifuge.


Detergent Tolerance≤5% Triton X-100, ≤5% Tween-20, ≤5% Sarkosyl, ≤0.1% SDS
Elution Volume≥ 150 µl
EquipmentMicrocentrifuge and centrifuge or vacuum source.
PurityHighly purified DNA is eluted with water and is especially well suited for sequencing, ligation reactions, and restriction endonuclease digestions.
Sample Source DNA from PCR, endonuclease digestions, DNA modification reactions, isotope/fluorescence labeling reactions, etc.
Size Range50 bp to 23 kb
Yield≤ 100 µg total DNA can be recovered.For DNA 50 bp to 10 kb the recovery is 70-95%. For DNA 11 kb to 23 kb the recovery is 50-70%.

Q1: What is the lower limit and minimal amount of DNA that can be recovered?

Picogram levels of DNA can be recovered. The limitation is based on sensitivity of detection method.

Q2: How to process naked DNA stored in DNA/RNA Shield?

Use the standard protocol (add 2 or 5 volumes of DNA binding buffer depending on DNA size).

Q3: What to do if ethanol addition to the DNA Wash Buffer was omitted?

The DNA will be eluted off the column. Rebind samples using the appropriate amount of DNA Binding Buffer and wash the column with the properly prepared wash buffer.

Q4: What happens if more DNA was loaded on the columns than the stated maximum binding capacity?

Oversaturation of the column can result in total DNA loss due to clogging of silica matrix.

Q5: How many times can columns be reloaded?

We recommend no more than 5 times as binding efficiency might decrease.

Q6: What is the minimum input volume of DNA sample?

Working with volumes below 50 µl can result in decreased recovery. We recommend raising the starting volume to 100 µl with water to ensure optimal binding conditions.




“This kit performed as described. I was able to obtain good quality and yield of the DNA -better than with a couple of competitor"s kits.”

-Kathleen B. (SUNY-ESF)

“The simple steps and washing instructions were excellent. DNA was ready for use for PCR and gave strong results.”

-Tyler C.

“It was a very simple procedure and it gave a concentration ten times the original amount.”

-Kimberly M. (University of Pennsylvania)
Read More

Cat #NameSizePrice
D4003-2-48DNA Wash Buffer (Concentrate)48 ml$60.00
D4004-1-LDNA Binding Buffer100 ml$57.00
D4003-2-24DNA Wash Buffer (Concentrate)24 ml$33.00
D4003-1-LDNA Binding Buffer50 ml$33.00
D3004-4-10DNA Elution Buffer10 ml$14.00
C1001-1000Collection Tubes1000 Pack$90.00
C1001-500Collection Tubes500 Pack$52.00
C1016-25Zymo-Spin V Columns w/ Reservoir25 Pack$67.00
C1016-50Zymo-Spin V Columns w/ Reservoir50 Pack$105.00
C1001-50Collection Tubes50 Pack$15.00
Zymo Research Corporation在生物医学领域做出了巨大贡献,仅在短短二十年间推出的众多产品就证明了这一点。简化和加快DNA / RNA分离过程一直是该公司的主要重点。在2001年,他们进入了新兴的表观遗传学领域,并迅速成为该市场的主要参与者之一。