EnzyFluo™ Myeloperoxidase Assay Kit

EnzyFluo™ Myeloperoxidase Assay Kit Catalog No: EMPO-100
Price: $339 Qty:
For orders of 10 or more kits, please call +1-510-782-9988x1 oremail us for best pricing and/or bulk order. Shipping: On Ice Shipment: Fedex ServiceDelivery: 1-2 days (US), 3-6 days (Intl) Storage: -20°C
Myeloperoxidase Assay Kit
  • Product Overview
  • Product FAQ
  • Product Citations
  • Assay Service
ProtocolSDS

Application

  • MPO peroxidation activity determination in biological samples (e.g. cell lysates, tissues, etc.)

Key Features

  • Fast and sensitive. Linear detection range (20 µL sample): 0.0025 to 2 U/L for 10 min reaction at 25°C.
  • Convenient and high-throughput. Homogeneous "mix-incubate-measure" type assay. Can be readily automated on HTS liquid handling systems for processing thousands of samples per day.

Method

  • FL530/585nm

Samples

  • Cell lysates, tissues, etc

Species

  • All

Size

  • 100 tests

Detection Limit

  • 0.0025 U/L

Shelf Life

  • 6 months

More Details

  • MYELOPEROXIDASE (MPO; EC 1.11.2.2) is a peroxidase enzyme and can be found in neutrophil, monocytes, and some soft tissue macrophages. MPO has an ability to use chloride as a cosubstrate with hydrogen peroxide to generate hypochlorous acid, a powerful antimicrobial agent produced by neutrophils. However, an excessive production of hypochlorous acid can lead to oxidative stress and tissues damage. Inflammation may also result when MPO oxidizes various substances such as phenols and anilines. Studies show that increased MPO levels may increase the risk of myocardial infarction and cardiovascular disease. BioAssay Systems EnzyFluoTM myeloperoxidase (MPO) assay kit is based on the MPO enzyme reaction with hydrogen peroxide (H2O2) which oxidizes the dye reagent to a highly fluorescent product. The fluorescence intensity of this product, measured at &labda;ex/em = 530/585 nm, is proportional to the total peroxidation activity in the sample. The provided MPO inhibitor is used to suppress peroxidase activity due to MPO in order to differentiate other peroxidase activities that may be present in the samples. Related Categories:Oxidative-Stress.htm" target=_blank>Oxidative Stress, Enzyme-Activity-Assays.htm" target=_blank>Enzyme Activity Assays

What samples have you tested?

The assay kit has been tested in purified myeloperoxidase, tissue and cell samples. Please follow the directions on the protocol for sample pretreatment.

What is the benefit of using a myeloperoxidase inhibitor in the assay?

The provided MPO inhibitor is used to suppress peroxidase activity due to MPO in order to differentiate other peroxidase activities that may be present in the samples. The difference in fluorescence intensities between sample and this sample blank is used to compute enzyme activity specifically due to myeloperoxidase.

I don"t have the correct wavelength filter, what other wavelength(s) would work?

The assay can be measured at excitation 500-540 nm and emission at 560-590 nm. Reading outside this range will result in a significant decrease in sensitivity.

Will the assay kit work in a 384 well plate?

Yes, the assay can be used in any standard plate. Simply adjust the sample and reagent volumes accordingly. For 384 well use 20-90 µL final reaction volume.

Can I store unused reagents for future use?

Yes, unused reagents can be stored according to the assay protocol. Repeated freeze/thaw cycles of reagents should be avoided. Working Reagents should be made fresh for each assay and used within 1 hour.

Do I need to use a standard or standard curve with each assay run?

Yes, it is highly recommended run the resorufin standard in each assay.For more detailed product information and questions, please feel free to Contact Us. Or for more general information regarding our assays, please refer to our General Questions.
Hashim, A. A., Helmy, M. M., & Mouneir, S. M. (2018). Cysteinyl leukotrienes predominantly mediate cisplatin-induced acute renal damage in male rats. Journal of Physiology and Pharmacology, 69(5), 779-787. Assay: Myeloperoxidase in rat kidney. Helmy, M. M., Hashim, A. A., & Mouneir, S. M. (2018). Zileuton alleviates acute cisplatin nephrotoxicity: Inhibition of lipoxygenase pathway favorably modulates the renal oxidative/inflammatory/caspase-3 axis. Prostaglandins & other lipid mediators, 135, 1-10. Assay: Myeloperoxidase in rat tissue.To find more recent publications, pleaseclick here.
If you or your labs do not have the equipment or scientists necessary to run this assay, BioAssay Systems can perform the service for you.Simply send us your samples:- Fast turnaround - Quality data - Low costPlease email or call 1-510-782-9988 x 2 to request assay service.
BioAssay Systems酸性磷酸酶(ACP)是一种在消化过程中催化磷酸基团从其他分子上裂解的酶。酸性磷酸酶可以在溶酶体中发现,并在与内体融合,酸化pH值后变得有活性,从而为ACP创造了最佳环境。ACP还可以在骨骼,脾脏,肝脏,肾脏和血液中发现。血清水平可以用作前列腺癌的生物标志物,尽管前列腺特异性抗原(PSA)被更广泛地使用。BioAssay Systems非放射性比色ACP分析基于从合成底物上裂解对硝基苯酚。加入终止剂后,对硝基苯酚会显色。加入终止剂后在405 nm处吸光度的增加与酶活性成正比。