QuantiChrom™ Bilirubin Assay Kit

QuantiChrom™ Bilirubin Assay Kit Catalog No: DIBR-180
Price: $299 Qty:
For orders of 10 or more kits, please call +1-510-782-9988x1 oremail us for best pricing and/or bulk order. Shipping: RT Shipment: Fedex ServiceDelivery: 1-2 days (US), 3-6 days (Intl) Storage: 4°C
Bilirubin Assay Kit
  • Product Overview
  • Product FAQ
  • Product Citations
  • Assay Service
ProtocolSDS

Application

  • For quantitative determination of bilirubin and evaluation of drug effects on bilirubin metabolism.

Key Features

  • Sensitive and accurate. Detection limit 0.16 mg/dL bilirubin in 96-well plate assay.
  • Simple and high-throughput. The procedure involves addition of a single working reagent and incubation for 10 min. Can be readily automated as a high-throughput assay in 96-well plates for thousands of samples per day.

Method

  • OD530nm

Samples

  • Serum

Species

  • All

Size

  • 180 tests

Detection Limit

  • 0.16 mg/dL

Shelf Life

  • 12 months

More Details

  • BILIRUBIN is one of the degradation products of hemoglobin formed when red blood cells die. Bilirubin exists in the insoluble unconjugated form (also indirect bilirubin), or soluble glucuronide conjugated form bilirubin (also direct bilirubin). Conjugated bilirubin moves into the bile canaliculi of the liver and then to the gall bladder. When stimulated by eating, bile (including the conjugated bilirubin) is excreted into the small intestine, where bilirubin is converted into urobilinogen. Bilirubin is a key diagnostic indicator. High levels of bilirubin result when too much hemoglobin is broken down or the removal of bilirubin does not function properly. The accumulation of bilirubin in the body causes jaundice. Simple and automation-ready procedures for quantitative determination of bilirubin find wide applications in research and drug discovery. BioAssay Systems bilirubin assay kit is designed to measure bilirubin in blood specimen in 96-well or cuvette formats. The improved Jendrassik-Grof method utilizes the reaction of bilirubin with diazotized sulfanilic acid, in which a red colored product is formed. The intensity of the color, measured at 510-550nm, is an accurate measure of the bilirubin level in the sample. Total bilirubin is assessed using caffeine benzoate to split bilirubin from the unconjugated bilirubin protein complex.

I would like to know whether your calibrator is bilirubin conjugate or unconjugated bilirubin or a combination of the two. If it is a combination of the two what is the proportion?

Bilirubin is not stable which is why we do not provide bilirubin as calibrator or standard. The calibrator is a dye that is stable and absorbs at the same wavelength as the product in the bilirubin color reaction. The absorbance (OD) is used to calculate the bilirubin concentration in the sample.

How does this measure conjugated bilirubin in comparison to bilirubin?

The conjugated bilirubin (also called direct bilirubin) is measured directly in the reaction with the diazotized sulfanilic acid, whereas the total bilirubin (conjugated + unconjugated) is measured in the presence of caffeine benzoate, which splits bilirubin from the unconjugated bilirubin protein complex.For more detailed product information and questions, please feel free to Contact Us. Or for more general information regarding our assays, please refer to our General Questions.
Nguyen, N. H., Le, T. V., Do, H. Q., Dang, T. M., Nguyen, Y. K., Vo, N. H., & Truong, N. H. (2018). human adipose-derived stem cells pre-treated with platelet-rich plasma and hepatocyte growth factor alleviate liver fibrosis in mice. Biomedical Research and Therapy, 5(5), 2332-2348. Assay: Bilirubin in mice serum.Matsushima, A., Oda, K., Mori, N., & Murakami, T. (2017). Modulation of multidrug resistance-associated proteins function in erythrocytes in glycerol-induced acute renal failure rats. Journal of Pharmacy and Pharmacology, 69(2), 172-181. Assay: Bilirubin in ureamic plasma. Sharabi, K., Lin, H., Tavares, C. D., Dominy, J. E., Camporez, J. P., Perry, R. J. & Bennion, M. (2017). Selective chemical inhibition of PGC-1alpha gluconeogenic activity ameliorates type 2 diabetes. Cell, 169(1), 148-160. Assay: Bilirubin in rabbits serum. Thongdee, P., & Na-Bangchang, K. (2017). The role of heme-oxygenase-1 in pathogenesis of cerebral malaria in the co-culture model of human brain microvascular endothelial cell and ITG Plasmodium falciparum-infected red blood cells. Asian Pacific journal of tropical medicine, 10(1), 20-24. Assay: Bilirubin in human brain cells. Van Le, T., Nguyen, N. H., Do, H. Q., Le, H. M., & Truong, N. H. (2017). Transplantation of umbilical cord blood-derived mesenchymal stem cells to treat liver cirrhosis in mice: a comparison of tail and portal vein injection. Progress in Stem Cell, 4(2), 201-216. Assay: Bilirubin in enterococcus faecalis liver cells. DIBR-180 Kita, S., & Textversion, E. T. D. (2016). The protective effect of transplanted liver cells into the mesentery on the rescue of acute liver failure after massive hepatectomy (Dissertation). Cell transplantation 25.8 (2016): 1547-1559. Assay: Bilirubin in rats serum. Li, Z., et al. (2016). Liver serine palmitoyltransferase activity deficiency in early life impairs adherens junctions and promotes tumorigenesis. Hepatology, 64(6), 2089-2102. Assay: Bilirubin in mice bile acid. Masuzaki, R., Zhao, S., Valerius, M. T., Tsugawa, D., Oya, Y., Ray, K. C., & Karp, S. J. (2016). SOCS2 balances metabolic and restorative requirements during liver regeneration. Journal of Biological Chemistry, 291(7), 3346-3358. Assay: Bilirubin in mice serum. Truong, N. H., Nguyen, N. H., Le, T. V., Vu, N. B., Huynh, N., Nguyen, T. V. & Pham, P. V. (2016). Comparison of the treatment efficiency of bone marrow-derived mesenchymal stem cell transplantation via tail and portal veins in CCl4-induced mouse liver fibrosis. Stem Cells International, 2016. Assay: Bilirubin in mice venous blood.Park SW, et al (2011). Cytokines induce small intestine and liver injury after renal ischemia or nephrectomy. Lab Invest. 91(1):63-84. Assay: Bilirubin in mouse plasma. Sekiya, S, Suzuki, A (2011). Direct conversion of mouse fibroblasts to hepatocyte-like cells by defined factors. Nature 475(7356):390-3. Assay: Bilirubin in mouse plasma. Siciliano A, et al (2011). Abnormal modulation of cell protective systems in response to ischemic/reperfusion injury is important in the development of mouse sickle cell hepatopathy. Haematologica. 96(1):24-32. Assay: Bilirubin in mouse blood. Akachi T, et al (2010). 1-methylmalate from camu-camu (Myrciaria dubia) suppressed D-galactosamine-induced liver injury in rats. Biosci Biotechnol Biochem.74(3):573-8. Assay: Bilirubin in rat plasma. Fu YY, et al (2010). Hyperbilirubinemia reduces the streptozotocin-induced pancreatic damage through attenuating the oxidative stress in the Gunn rat. Tohoku J Exp Med. 222(4):265-73. Assay: Bilirubin in rat plasma. Holt MP, et al (2010). Exacerbation of acetaminophen-induced disturbances of liver sinusoidal endothelial cells in the absence of Kupffer cells in mice. Toxicol Lett. 194(1-2):34-41. Assay: Bilirubin in mouse blood. Hyvelin JM, et al (2010). Hemin prevents in-stent stenosis in rat and rabbit models by inducing heme-oxygenase-1. J Vasc Surg. 51(2):417-28. Assay: Bilirubin in rat blood. Okura H,et al (2010). Properties of hepatocyte-like cell clusters from human adipose tissue-derived mesenchymal stem cells. Tissue Eng Part C Methods. 16(4):761-70. Assay: Bilirubin in human, mouse serum, tissue. Vera T, Stec DE (2010). Moderate hyperbilirubinemia improves renal hemodynamics in ANG II-dependent hypertension. Am J Physiol Regul Integr Comp Physiol. 299(4):R1044-9. Assay: Bilirubin in mouse blood. Zhang, Z et al (2010). Preclinical assessment of simultaneous targeting of epidermal growth factor receptor (ErbB1) and ErbB2 as a strategy for cholangiocarcinoma therapy. Hepatology 52(3):975-86. Assay: Bilirubin in rat blood. Beppu F. et al (2009) Single and repeated oral dose toxicity study of fucoxanthin (FX), a marine carotenoid, in mice. J. Toxicol. Sci. 34(5): 501-510. Assay: Bilirubin in mouse plasma. Nedredal GI, et al (2009) Optimization of mass transfer for toxin removal and immunoprotection of hepatocytes in a bioartificial liver. Biotechnol Bioeng.104(5): 995-1003. Assay: Bilirubin in human tissue. Sirica AE,et al (2008). A novel "patient-like" model of cholangiocarcinoma progression based on bile duct inoculation of tumorigenic rat cholangiocyte cell lines. Hepatology 47(4):1178-90. Assay: Bilirubin in rat serum. Vinchi F. et al (2008) Hemopexin Prevents Endothelial Damage and Liver Congestion in a mouse Model of Heme Overload. Am J Pathol. 2008 July; 173(1): 289-299. Assay: Bilirubin in mouse serum.To find more recent publications, pleaseclick here.
If you or your labs do not have the equipment or scientists necessary to run this assay, BioAssay Systems can perform the service for you.Simply send us your samples:- Fast turnaround - Quality data - Low costPlease email or call 1-510-782-9988 x 2 to request assay service.
BioAssay Systems酸性磷酸酶(ACP)是一种在消化过程中催化磷酸基团从其他分子上裂解的酶。酸性磷酸酶可以在溶酶体中发现,并在与内体融合,酸化pH值后变得有活性,从而为ACP创造了最佳环境。ACP还可以在骨骼,脾脏,肝脏,肾脏和血液中发现。血清水平可以用作前列腺癌的生物标志物,尽管前列腺特异性抗原(PSA)被更广泛地使用。BioAssay Systems非放射性比色ACP分析基于从合成底物上裂解对硝基苯酚。加入终止剂后,对硝基苯酚会显色。加入终止剂后在405 nm处吸光度的增加与酶活性成正比。