asuragen/QuantideX® qPCR BCR-ABL IS Kit/60/86003

价格
面议
货号:86003
浏览量:127
品牌:asuragen
服务
全国联保
正品保证
正规发票
签订合同
商品描述

QuantideX® qPCR BCR-ABL IS Kit

BCR-ABL blood cancer cells

Assessing complete molecular response requires the highest possible assay sensitivity. The FDA-cleared QuantideX® qPCR BCR-ABL IS Kit takes chronic myeloid leukemia (CML) monitoring to a new level of sensitivity – 0.002% IS (MR4.7). It’s a qPCR-based in vitro Diagnostic test for the quantitation of BCR-ABL1 and ABL1 transcripts in total RNA from whole blood of diagnosed t(9;22) positive CML patients expressing e13a2 and/or e14a2 fusion transcripts.

Features & Benefits

The QuantideX qPCR BCR-ABL IS Kit’s unprecedented level of sensitivity coupled to a simple-to-run, singlicate test, allows labs to reliably and reproducibly monitor much deeper molecular response.

Reduced ComplexityEase-of-data analysis and reporting:

  • Direct reporting on the International Scale (IS): No sample exchange or conversion factor calculations required
  • Data analysis software eliminates manual intervention to provide automated calculations and streamlined reporting

Optimized WorkflowValuable operator hands-on time has been significantly reduced through:

  • Multiplexed design amplifies and detects both fusion and control gene in the same reaction
  • All-inclusive reagents sourced and Quality Controlled together from a single vendor
  • Pre-mixed reagents leading to fewer pipetting steps in the mastermix preparation

Quality PerformanceDetecting BCR-ABL Transcripts robustly, reliably with a highly sensitive assay:

  • Limit of Detection (LOD) of MR4.7 (0.002%IS): 95% detection at LOD as determined using human RNA specimens
  • Increased analytical sensitivity without compromising analytical specificity: Non-CML (major) transcripts not detected in assay
  • Armored RNA®-based standards providing true RNA quantification for a quantitative RNA assay
  • Robust performance as indicated by minimum variability of replicate measurements

Download Brochure

Analytical Characteristics

  • Proven sensitivity based on rigorous testing criterion (Table 1)
  • Minimal variability across entire dynamic range of %IS values (Table 2)
  • Multiplexed design leads to workflow and cost efficiency (Figure 1)

Proven Sensitivity Based on Rigorous Testing CriterionBCR-ABL US-IVD Table 1Table 1: LOD as determined by CLSI EP17-A2 guidelines by testing Human RNA dilutions ranging from MR4.4 to MR6: 60 replicates of each dilution for a total of 1680 data points

Minimal Variability Across Entire Dynamic Range of %IS ValuesQdeX BCR-ABL US-IVD Table2Table 2: Precision evaluated by testing 5 different MR levels, using 3 operators, 9 runs for a total of 450 data points*The fold change column represents summarized data for clarification purpose only. To see full precision data, please refer to Table 4 of the Instruction for Use.

Multiplexed Design Leads to Workflow and Cost EfficiencyFigure 3a AsuragenPlate Layout Figure 3b CompetitorPlate2016

Figure 1: Comparison of a plate layout for 8 sample run on Asuragen plate (left) and an alternate non-multiplex assay (right): 19 reactions for Asuragen setup vs. 60-64 reactions on a non-multiplex assay setup

Additional Resources

Videos

Defining the Standard of Care: FDA-Cleared, Clinically Proven CML Monitoring at the MR 4.7 Level

Analytical Validation of a BCR-ABL1 Monitoring System that Surpasses Current Testing Requirements

Simple, Sensitive, and Scalable Patient Monitoring with the QuantideX® qPCR BCR-ABL IS Kit

Posters

BCR-ABL1 Monitoring on the IS Using a Clinically and Analytically Validated Multiplex Assay Directly Aligned to the WHO Primary Standards and that Unifies Reporting FormatsView full poster

Modifications to RNA Isolation Protocols Meet Requirements for Modern CML Monitoring of BCR-ABL1 Transcript LevelsView full poster

Validation of BCR-ABL1 Test Performance from Whole Blood Stored up to 72 Hours Facilitates Operational Flexibility and Expanding Locally Managed CML MonitoringView full poster

Publications

Establishment of the first World Health Organization International Genetic Reference Panel for quantitation of BCR-ABL mRNA. White et. al. Blood. 2010;116(22):e111-7. doi: 10.1182/blood-2010-06-291641. Epub 2010 Aug 18

Establishment of a standardized multiplex assay with the analytical performance required for quantitative measurement of BCR-ABL1 on the international reporting scale. Brown et. al. Blood Cancer J. 2011;1(3):e13. doi: 10.1038/bcj.2011.10. Epub 2011 Mar 25

Establishment and validation of analytical reference panels for the standardization of BCR-ABL1 quantitative measurements on the international scale. White et. al. Clin Chem. 2013 Mar 7. [Epub ahead of print]

Browse all Publications

The test is not intended for the diagnosis of CML or for monitoring rare transcripts resulting from t(9;22).

Ordering

Product NameNumber of ReactionsCatalog Number
QuantideX® qPCR BCR-ABL IS Kit6049574

T 1-877-777-1874; 512-681-5200 F 512-681-5202 E orders@asuragen.com

View Sales Contacts

QuantideX® qPCR BCR-ABL IS Kit

There’s only one way to detect complete molecular response (CMR) – with a more sensitive assay. The QuantideX® qPCR BCR-ABL IS Kit takes chronic myeloid leukemia (CML) monitoring to a new level of sensitivity – 0.002% IS (MR4.7). It’s a qPCR-based in vitro Diagnostic test for the quantitation of BCR-ABL1 and ABL1 transcripts in total RNA from whole blood of diagnosed t(9;22) positive CML patients expressing e13a2 and/or e14a2 fusion transcripts.

Features & Benefits

ceivdThe QuantideX qPCR BCR-ABL IS Kit provides labs with a robust and reliable method for monitoring leukemia patients, also allowing them to keep pace with the advances in TKI therapy.

Reduced ComplexityEase-of-data analysis and reporting:

  • Direct reporting on the International Scale (IS): No sample exchange or conversion factor calculations required
  • Data analysis software eliminates manual intervention to provide automated calculations and streamlined reporting

Optimized WorkflowValuable operator hands-on time has been significantly reduced through:

  • Multiplexed assay design that amplifies and detects both fusion and control gene in the same reaction
  • All-inclusive reagents sourced and Quality Controlled together from a single vendor
  • Pre-mixed tubes leading to fewer pipetting steps in the mastermix preparation 

Quality PerformanceDetecting BCR-ABL Transcripts robustly, reliably with a highly sensitive assay:

  • Sensitivity of MR4.7 (0.002%IS): 95% positivity at this LOD as determined by testing human RNA specimens
  • Increased sensitivity without compromising specificity: Non-CML (major) transcripts not detected by the assay
  • Armored RNA based standards providing true RNA quantification for a quantitative RNA assay
  • Robust performance as indicated by minimum variability of replicate measurements

Analytical Characteristics

  • Proven sensitivity based on rigorous testing criterion (Figure 1)
  • Minimal variability across the entire dynamic range of % IS values (figure 2)
  • Multiplexed design leads to workflow and cost efficiency (figure 3)

Proven Sensitivity Based on Rigorous Testing CriterionFigure 1 Probit_US_IVDweb

Figure 1: LOD as determined by CLSI EP17-A2 guidelines by testing Human RNA dilutions ranging from MR4.4 to MR6: 60 replicates of each dilution for a total of 1260 data points

Minimal Variability Across Entire Dynamic Range of %IS ValuesTable 1 BCRABL IS Kit

Figure 2. Precision was evaluated by using 5 different levels of positive specimen, tested by 3 operators over 20 runs. Each level was tested 40 times to obtain Standard Deviations

Multiplexed Design Leads to Workflow and Cost EfficiencyFigure 3a AsuragenPlate LayoutFigure 3b CompetitorPlate2016

Figure 3: Comparison of a plate layout for 8 sample run on Asuragen plate (left) and an alternate non-multiplex assay (right): 19 reactions for Asuragen setup vs. 60-64 reactions on a non-multiplex assay setup

Additional Resources

Videos

Defining the Standard of Care: FDA-Cleared, Clinically Proven CML Monitoring at the MR 4.7 Level

Analytical Validation of a BCR-ABL1 Monitoring System that Surpasses Current Testing Requirements

Simple, Sensitive, and Scalable Patient Monitoring with the QuantideX® qPCR BCR-ABL IS Kit

Posters

BCR-ABL1 Monitoring on the IS Using a Clinically and Analytically Validated Multiplex Assay Directly Aligned to the WHO Primary Standards and that Unifies Reporting FormatsView full poster

Modifications to RNA Isolation Protocols Meet Requirements for Modern CML Monitoring of BCR-ABL1 Transcript LevelsView full poster

Validation of BCR-ABL1 Test Performance from Whole Blood Stored up to 72 Hours Facilitates Operational Flexibility and Expanding Locally Managed CML MonitoringView full poster

Publications

Establishment of the first World Health Organization International Genetic Reference Panel for quantitation of BCR-ABL mRNA. White et. al. Blood. 2010;116(22):e111-7. doi: 10.1182/blood-2010-06-291641. Epub 2010 Aug 18

Establishment of a standardized multiplex assay with the analytical performance required for quantitative measurement of BCR-ABL1 on the international reporting scale. Brown et. al. Blood Cancer J. 2011;1(3):e13. doi: 10.1038/bcj.2011.10. Epub 2011 Mar 25

Establishment and validation of analytical reference panels for the standardization of BCR-ABL1 quantitative measurements on the international scale. White et. al. Clin Chem. 2013 Mar 7. [Epub ahead of print]

Browse all Publications

The test is not intended for the diagnosis of CML or for monitoring rare transcripts resulting from t(9;22).

Ordering

Product NameNumber of ReactionsCatalog Number
QuantideX® qPCR BCR-ABL IS Kit6086003

T 1-877-777-1874; 512-681-5200 F 512-681-5202 E orders@asuragen.com

View Sales Contacts
asuragen的AmplideX®PCR / CE HTT试剂盒 AmplideX PCR / CE  HTT 试剂盒*使HTT  基因中CAG三核苷酸重复序列的检测和确定  比以往更加容易。只需一次PCR反应,该测定法即可克服相邻SNP的挑战,可变的CCG重复序列可准确可靠地报告一天中重复序列的数量,从10ng gDNA即可。  特点与优势分析特性订购信息特点与优势AmplideX PCR / CE HTT试剂盒包含用于对HTT CAG重复区域进行两引物,锚定引物PCR的试剂,然后通过毛细管电泳确定片段大小。这种单管PCR反应提供了简化的工作流程,使用现成的实验室设备可以在大约6小时内得到样品。降低复杂度专有的PCR解决方案,用于富含GC的扩增和检测消除了对多个PCR的需求–一个结果,简单的分析解决接合性并检测大扩展优化的工作流程配套齐全的端到端解决方案,可大大减少动手时间一次转换即可实现样品到结果与AmplideX PCR / CE DMPK试剂盒相同的PCR和CE条件质量结果可靠,明确的结果和稳定的峰峰值模式在整个CAG重复范围内准确调整大小软件将原始碱基对数据转换为重复数