Assaypro/人抗凝血酶III(AT3)AssayMax-ELISA试剂盒/96孔板/EA3301-1

价格
¥6800.00
货号:EA3301-1
浏览量:114
品牌:Assaypro
服务
全国联保
正品保证
正规发票
签订合同
商品描述
DETAILS
Description:This assay employs a quantitative enzyme immunoassay technique that measures the specified antigen in samples.
Type:AssayMax ELISA Kits
Samples:

Cell Culture

Urine

Saliva

Milk

CSF

Catalog Number:EA3301-1
Species:Human
Format:Sandwich ELISA
Size:96 Well Plate
Range:3.125 - 200 ng/ml; 0.005 - 0.3 mIU/ml
Research Area:Cardiovascular
Entrez Gene:462
Omim:107300
UniProt:P01008
Unigene:Hs.75599
Synonyms:Antithrombin III, Antithrombin-III, ATIII, Serpin C1, AT3, PRO0311
Note:For Research Use Only, Not To Be Used For Diagnostic Purposes
Product References:
*Oberbach A et al. (2011) Combined Proteomic and Metabolomic Profiling of Serum Reveals Association of the Complement System with Obesity and Identifies Novel Markers of Body Fat Mass Changes. J Proteome Res. 10(10):4769-88* Andersen RF et al. (2012) Plasma and urine proteomic profiles in childhood idiopathic nephrotic syndrome. Proteomics Clin Appl. 6(7-8):382-93*Saleh AAW et al. (2014) Markers of Inflammation and Thrombophilia in Psoriasis. Med. J. Cairo Univ. 82(1):127-131*Sehgal A et al. (2015) An RNAi therapeutic targeting antithrombin to rebalance the coagulation system and promote hemostasis in hemophilia. Nature Medicine 21(5):492-497* Nair JK et al. (2017) Impact of enhanced metabolic stability on pharmacokinetics and pharmacodynamics of GalNAc?siRNA conjugates. Nucleic Acids Res. 45(19):10969-10977. doi: 10.1093/nar/gkx818* Schochl H et al. (2017) Dual inhibition of thrombin and activated factor X attenuates disseminated intravascular coagulation and protects organ function in a baboon model of severe Gram-negative sepsis. Critical Care. 21(1):51* Selmeczi A et al. (2017) Antithrombin Debrecen (p. Leu205Pro)?Clinical and molecular characterization of a novel mutation associated with severe thrombotic tendency. Thromb Res. 158:1-7* Chan KC et al. (2019) Astaxanthin attenuated thrombotic risk factors in type 2 diabetic patients. Journal of Functional Foods. 53:22-27* Premkumar M et al. (2019) Coagulation failure is associated with bleeding events and clinical outcome during systemic inflammatory response and sepsis in acute?on?chronic liver failure: An observational cohort study. Liver Int. 39(4):694-704
Assaypro单克隆原发性抗体我们所有的抗体都是根据美国ISO 9001认证的质量管理体系生产的。抗体可与多种结合物使用,包括生物素,HRP,FITC,RPE,APC和PerCP。通过使用内部开发的专有标记技术,我们可以在保护抗体结合能力和亲和力的同时对抗体进行过度标记。建议的用途包括免疫测定,蛋白质印迹,免疫荧光,免疫细胞化学,免疫组织化学和流式细胞仪。应用范围:免疫测定蛋白质印迹(WB)免疫荧光(IF)免疫细胞化学(ICC)免疫组化(IHC)流式细胞仪(FACS)