- Jackson ImmunoResearch Secondary Antibody Resource
- lbe吧LBE安全大师,专注Android平台防护安全!2008年,...
- 澳大利亚(澳大利亚联邦)
- ...Jackson ImmunoResearch价格更新 Jackson胶体金标记Jackson品...
- Jackson ImmunoResearch/Jakcson 二抗/Jackson 公司
- Jackson特色产品专题一:远红光/红外检测Western Blotting荧光二抗自...
- Jackson公司,Jackson ImmunoResearch代理商,jacksonimmuno经销...
- Jackson ImmunoResearch中国特约代理商(2021年度)
- Alexa Fluor® 594AffiniPure Goat AntiRat IgM, µ Chain Spec...
- ...Specific Antibodies,,Jackson代理,产品目录Jackson冻干粉二抗,抗...
- 恭喜蚂蚁淘获得Jackson公司代理中国总代理授权_
- Jackson过氧化物酶标记的羊抗人IgG多克隆抗体_jackson...
Storage and Rehydration: Store freeze-dried solid at 2-8°C. Rehydrate with the indicated volume of dH2O (see product specification sheet) and centrifuge if not clear. Prepare working dilution on day of use. Product is stable for about 6 weeks at 2-8°C as an undiluted liquid.Extended Storage after Rehydration: Aliquot and freeze at -70°C or below. Avoid repeated freezing and thawing. Alternatively, add an equal volume of glycerol (ACS grade or better) for a final concentration of 50%, and store at -20°C as a liquid. Expiration date: one year from date of rehydration. The expiration date may be extended if test results are acceptable for the intended use.
Purity:The IgG fraction was purified from mouse ascites by chromatographic procedures not involving affinity purification. Buffer: 0.01M Sodium Phosphate, 0.25M NaCl, pH 7.6 Stabilizer:15 mg/ml Bovine Serum Albumin (IgG-Free, Protease-Free) Preservative:0.05% Sodium Azide ConjugateCyanine Cy™3
Amax: 550Emax: 570nmCy3 is brighter, more photostable, and gives less background than other orange-red fluorescing dye conjugates. Cy3 conjugates can be excited maximally at 550 nm, with peak emission at 570 nm. For fluorescence microscopy, Cy3 can be visualized with traditional tetramethyl rhodamine (TRITC) filter sets, since the excitation and emission spectra are nearly identical to those of TRITC. We recommend Cy3 as a brighter alternative to TRITC. Cy3 can be excited to about 50% of maximum with an argon laser (514 nm or 528 nm lines), or to about 75% of maximum with a helium/neon laser (543 nm line) or mercury lamp (546 nm line). Cy3 has been used with fluorescein for double labeling; however, the use of a narrow band-pass emission filter for fluorescein is recommended to minimize Cy3 fluorescence in the FITC filter set. Cy3 can also be paired with Alexa Fluor® 647 for multiple labeling when using a confocal microscope. However, a better choice for multiple labeling is Rhodamine Red-X because its fluorescence is midway between a green fluorescing dye (like Alexa Fluor® 488) and a far-red-fluorescing dye like Alexa Fluor® 647.
Images & ReferencesThis product is for in vitro research use only. It is not a medical device and it is not intended for diagnostic or therapeutic purposes.
Cy is a trademark of GE Healthcare Bio-Sciences Ltd. Jackson ImmunoResearch is licensed by GE Healthcare Bio-Sciences Ltd. to manufacture and sell conjugates of Cy2, Cy3, and Cy5 reactive dyes under US Patent Number 5,268,486, and other patents pending.
Jackson是全球专业从事生产和销售亲和纯化的二抗和纯化免疫球蛋白的公司,其产品主要销往到世界各地的大学科研所和医院里的动物研究以及生物医学研究机构的科学家。蚂蚁淘科技有限公司作为Jackson中国区代理,可以向中国客户提供Jackson的全系列产品。下图为Jackson(jacksonimmuno)公司授权蚂蚁淘科技有限公司(Ebiomall Scientific Inc.)作为Jackson在中国区域的代理授权书。

